Mercury removal chemical for tanks and vessels

GreenSolvs HG01 is a ready-to-use, water-based solution sprayed inside tanks and vessels to help capture mercury vapour during decontamination and plant maintenance. Mildly alkaline, non-flammable, and made in our Johor Bahru plant.

Request QuotationWhatsApp our team
GreenSolvs HG01 Mercury Remover sample bottle
THE CHALLENGE

Mercury vapour makes tank entry dangerous

Natural gas and condensate from many fields carry trace mercury. Over time it settles inside separators, storage tanks, heat exchangers and pipework. When equipment is opened for turnaround or inspection, that mercury can vaporise and expose workers.

Mercury decontamination has to bring vapour levels down to your site's entry limits before anyone goes in, without adding a fire risk inside a confined space.

Tanks & vessels in mercury-bearing service

Decontamination of storage tanks, separators and process vessels before inspection.

Plant turnaround & shutdown

Maintenance work where crews may be exposed to mercury vapour.

Pre-entry preparation

Process equipment before inspection and maintenance entry.

THE PRODUCT

GreenSolvs HG01 Mercury Remover

GreenSolvs HG01

GreenSolvs HG01

Helps capture mercury vapour from internal surfaces and residues. Non-acidic and non-flammable, so it suits work inside closed tanks and vessels.

UseReady to use, do not dilute
ApplicationSpray / sprinkle inside the tank or vessel
BaseWater-based · pH 10 ± 0.5
AppearanceLight green, clear liquid, odourless
Density1.043 g/mL
Flash pointNot applicable, non-flammable
Packing20 kg · 200 kg · 1,000 L IBC
HOW IT IS USED

Directions for use

  1. 1
    Isolate & permit
    Isolate, drain and depressurise the tank or vessel under your site permit-to-work.
  2. 2
    Spray
    Spray HG01 directly onto internal surfaces and residues inside the closed tank or vessel.
  3. 3
    Monitor
    Measure mercury vapour continuously with a calibrated mercury analyser.
  4. 4
    Repeat
    Continue treatment until mercury vapour readings meet your site's entry limits.
  5. 5
    Collect
    Collect spent solution and residues. They contain mercury and must be disposed of as scheduled waste.
  6. 6
    Test before entry
    Ventilate and carry out a full gas and mercury vapour test before any person enters.


Contact Desans for site-specific application rates.

Safety note. HG01 helps reduce mercury vapour. It does not replace mercury monitoring, ventilation, permit-to-work or the respiratory protection required by your site's procedures. Treat all spent solution as mercury-contaminated waste. Results depend on the type and quantity of mercury present and must be confirmed by on-site monitoring.
ALSO FOR MERCURY + TOXIC GAS

Need H2S and SO2 treatment at the same time?

GreenSolvs TGR02 treats H2S, SO2 and mercury vapour in one water-based solution, applied by circulation, spray or soaking. See our tank degassing chemicals →

FREQUENTLY ASKED QUESTIONS

Common questions

What is a mercury remover used for?

It is sprayed inside tanks, vessels and process equipment that have been in mercury-bearing service, to help capture mercury vapour during decontamination so that maintenance and inspection can proceed safely.

Does GreenSolvs HG01 need to be diluted?

No. HG01 is ready to use and should not be diluted. It is sprayed or sprinkled directly onto internal surfaces and residues.

Is HG01 flammable?

No. HG01 is water-based with no flash point, which suits work inside closed tanks and vessels.

Can workers enter once HG01 has been applied?

Only after mercury vapour readings meet your site entry limits and a full gas and mercury vapour test has been carried out. HG01 does not replace monitoring, ventilation, permit-to-work or respiratory protection.

How should spent HG01 solution be disposed of?

Spent solution and residues from mercury-bearing equipment contain mercury. Collect them in labelled containers and dispose of them as scheduled waste through a licensed contractor, in line with local regulations.

What pack sizes are available?

20 kg pail, 200 kg plastic drum and 1,000 L IBC tank, produced to order in Johor Bahru.

Tell us about your site

Share the equipment, contamination and volume. Our lab will recommend the product, dosage and bulk packing, and quote for supply anywhere in Malaysia.

Request Quotation